Model EB-FVD01-A
IR Door Sensor Switches
Infrared door sensor switches that switch the light when a cabinet or wardrobe door opens.
Range
Models in this series
A few models that show how the series varies. It is not a full SKU list; the model for a project is confirmed in the quotation.
-
EB-FVD01-A
- Operating voltage
- DC12/24V
- Dimensions
- 39*31*8mm
Catalogue model FVD01-A; max load 3A/36W; cable in 140cm / out 180cm; catalogue first reading, to be confirmed
-
EB-FVD02-A
- Operating voltage
- DC12/24V
- Dimensions
- 30*15*6.2mm
Catalogue model FVD02-A; max load 5A/60W; cable in 150cm / out 15cm; catalogue first reading, to be confirmed
-
EB-FVD03-A
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD03-A; max load 5A/60W; cut-out (catalogue reading) 10mm; cable in 150cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD03-A-V2
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD03-A-V2; max load 60w; cable in 150cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD03-B
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD03-B; max load 5A/60W; cable in 150cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD03-B-V2
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD03-B-V2; max load 5A/60W; cut-out (catalogue reading) 010mm; cable in 150cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD03-A-V1
- Operating voltage
- DC12/24V
Catalogue model FVD03-A-V1; max load 5A/60W; cable in 100cm / out 100cm; catalogue first reading, to be confirmed
-
EB-FVD04-A
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD04-A; max load 5A/60W; cut-out (catalogue reading) 12mm; cable in 20cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD03-B-V1
- Operating voltage
- DC12/24V
Catalogue model FVD03-B-V1; max load 5A/60W; cable in 100cm / out 100cm; catalogue first reading, to be confirmed
-
EB-FVD04-B
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD04-B; max load 5A/60W; cut-out (catalogue reading) 12mm; cable in 20cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD04-A-V1
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD04-A-V1; max load 5A/60W; cut-out (catalogue reading) 12mm; cable in 20cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD04-A-1216
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD04-A-1216; max load 60w; cable in 100cm / out 100cm; catalogue first reading, to be confirmed
-
EB-FVD04-B-V1
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD04-B-V1; max load 5A/60W; cut-out (catalogue reading) 12mm; cable in 20cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD04-A-V2
- Operating voltage
- DC12/24V
- Sensing
- 3-7cm
Catalogue model FVD04-A-V2; max load 5A/60W; cut-out (catalogue reading) 12mm; cable in 150cm / out 20cm; catalogue note: 目录同名重复,先比较参数卡; catalogue first reading, to be confirmed
-
EB-FVD04-A-V2
- Operating voltage
- DC12/24V
- Sensing
- 5-8cm
Catalogue model FVD04-A-V2; max load 5A/60W; cut-out (catalogue reading) 010mm; cable in 100cm / out 100cm; catalogue note: 目录同名重复,先比较参数卡; catalogue first reading, to be confirmed
-
EB-FVD05-A-V1
- Operating voltage
- DC12/24V
Catalogue model FVD05-A-V1; max load 2A/24W; cut-out (catalogue reading) 14mm; cable in 15cm / out 15cm; catalogue first reading, to be confirmed
-
EB-FVD05-A
- Operating voltage
- DC12/24V
Catalogue model FVD05-A; max load 5A/60W; cut-out (catalogue reading) 014mm; cable in 150cm / out 20cm; catalogue first reading, to be confirmed
-
EB-FVD06-A
- Operating voltage
- DC12/24V
- Dimensions
- 45*27*14mm
Catalogue model FVD06-A; max load 5A/60W; cable in 150cm / out 15cm; catalogue first reading, to be confirmed
-
EB-FVD07-A
- Operating voltage
- DC12/24V
Catalogue model FVD07-A; max load 5A/60W; cable in 100cm / out 100cm; catalogue first reading, to be confirmed
-
EB-FVD09-B
- Operating voltage
- DC12/24V
- Dimensions
- 56*33*7.6mm
Catalogue model FVD09-B; max load 2A/24W; cable in 100cm / out 100cm; catalogue first reading, to be confirmed
-
EB-FVD08-B
- Operating voltage
- DC12/24V
- Dimensions
- 41.5*28*10mm
Catalogue model FVD08-B; max load 5A/60W; cable in 20cm / out 200cm; catalogue first reading, to be confirmed
-
EB-FVD10-B
- Operating voltage
- DC12/24V
- Dimensions
- 35*28.8*12.2mm
Catalogue model FVD10-B; max load 5A/60W; cable in 200cm / out 15cm; catalogue first reading, to be confirmed
-
EB-JHL-H211
- Operating voltage
- AC85-250V
- Dimensions
- 100*43*21mm
Catalogue model JHL-H211; max load 2A/500W; cable in 15cm / out 15cm; catalogue first reading, to be confirmed
Specifications
Specification
- Model
- EB-FVD01-A
- Dimensions
- 39*31*8mm
- Operating voltage
- DC12/24V
- Note
- Catalogue model FVD01-A; max load 3A/36W; cable in 140cm / out 180cm; catalogue first reading, to be confirmed
Key benefits
What this series solves
Infrared door sensor switches that switch the light when a cabinet or wardrobe door opens.
Models in the series differ in voltage, sensing distance, cut-out and cable length; each one is listed with the values recorded for it, and the model for a project is confirmed in the quotation.
- The light comes on with the door, without a mechanical contact
- Sensor and control box are separate on most models in the series
- DC 12/24 V and AC mains versions are listed separately
Next step
Send the drawing, the quantity and the destination.
That is enough for a first answer with price, lead time and the points still to confirm.